Statistical analysis of detuning effects for implantable microstrip antennas

Update Item Information
Publication Type thesis
School or College College of Engineering
Department Electrical & Computer Engineering
Author Johnson, Jeffrey D
Title Statistical analysis of detuning effects for implantable microstrip antennas
Date 2007-06-20
Description Microstrip antennas are an attractive option for biotelemetry communication between implanted medical devices and external control systems due to their small size and ability to be integrated with the implanted device. These antennas may be placed in the shoulder or chest cavity for cardiac devices, under the skin behind the ear for artificial hearing devices, or under the lens of the eye for retinal prostheses. Thus, the antenna's actual operating environment can have substantial variation due to placement location, differences between individuals, and also from uncertainties in the electrical properties of the biological tissues. These variations can be described statistically, and the purpose of this thesis is to evaluate the resultant variation in the antenna performance from these variations. In this thesis, we apply an analytical technique called the variational method to solve for the effective relative permittivity, ereff, and effective conductivity, aeff, of a microstrip antenna placed under muscle, fat, and skin layers with statistically variable thicknesses and electrical properties. The variational method was used to solve the quasistatic Poisson's equation for electric potential in a multilayered medium. The resulting integral expression was then solved numerically using a Monte Carlo simulation method by which the effects of tissue variations, discussed above, were studied. These simulations were used to calculate ereff and aeff for thousands of different configurations of dielectric layer thickness and constitutive parameters. These values were then used to quantify detuning effects such as shifts in resonant frequency and the resultant reduction in useable bandwidth of the implanted antenna. The simulations used two types of input data. First, the measured means and standard deviations for the constitutive parameters, sr and o, for muscle, fat, and skin tissues were used to generate randomly varying, normally distributed, electrical properties. Second, superstrate and tissue thicknesses were randomly chosen (uniformly distributed) within ranges considered appropriate for the particular area in the body being studied. The simulation data were statistically analyzed by fitting their empirical distributions to the lognormal distribution function. The parameters of these fitting functions were estimated and used to calculate confidence intervals on expected variations in resonant frequency. The effect of superstrate thickness on reduction of this variation was demonstrated.
Type Text
Publisher University of Utah
Subject Artificial implants; Biotelemetry communication
Dissertation Institution University of Utah
Dissertation Name MS
Language eng
Relation is Version of Digital reproduction of "Statistical analysis of detuning effects for implantable microstrip antennas" J. Willard Marriott Library Special Collections RD14.5 2007 .J64
Rights Management © Jeffrey D. Johnson
Format Medium application/pdf
Format Extent 43,183 bytes
Identifier us-etd2,127367
Source Original: University of Utah J. Willard Marriott Library Special Collections
Conversion Specifications Original scanned on Epson GT-30000 as 400 dpi to pdf using ABBYY FineReader 9.0 Professional Edition
ARK ark:/87278/s6zp4mkp
Setname ir_etd
ID 192356
Reference URL https://collections.lib.utah.edu/ark:/87278/s6zp4mkp